![]() ![]() Identified the hall effect current sensor used in the small drive units as the MLX91209. You can also specify a lower interval than the one of the variable, using pad as the inverse of thicken. By default it pads all observations between the first and the last observation, but you can use startval and endval to deviate from this. It was this trip coupled with the above issues relating to main contactor control and switching frequency that lead to inverter deaths. Also pad allows for deviations from its default behavior. The component choice in the opamp circuit on the open source board causes a hardware overcurrent event at +850A regardless of settings above this value thus limiting power. Now, I'm finding some free or in Appstore replacements for it. It is good but buying it is outside AppStore and I'm not really confident with that. 1V and 4.9V giving a total span of 1150A. TripMode is a software that lets the user blocks softwares from accessing the internet. ![]() ![]() Fault indicated by chart on front of instrument. Seems Tesla use the EXACT SAME hardware overcurrent detection circuit on their logic board as designed by Johannes. Detects Live - Earth/Neutral reversal by use of Polarity Test Pad. The tesla current sensors span +/- 1250A over a range of 0-5v with 2.5v representing 0A. Working on a fix for a hardware bug that is limiting power. This was tested to the Nth degree on my recent trip to Romania The small drive unit inverter works perfectly at 17.6khz switching frequency and setting tripmode to prechon ensures the pre charge resistor can provide a path back to the battery during release of the main contactor. NOT caused by overcurrent through the igbts but rather the combination of using 8.8kHz switching frequency through a very low inductance stator and the sudden release of the main contactor on an overcurrent detection. In No-trip mode the tester can be used with the mains lead MP-KAMP12 when testing at 13A socket outlets, or the distribution board lead. on the seat cushion with their seat belt on, legs comfortably extended and. It’s easy to use: simply enable this smart data blocker app directly in the menu bar and it will be launched anytime your Mac connects to that network. It automatically reduces your laptop data consumption once you use a mobile hotspot. Root cause of the drive unit inverter failures discovered and fixed. TripMode is the proper mobile data app for you, which offers peace of mind on the go. Sadly I can't make any video for a few days as I've lost my voice Anyway, here are few interesting discoveries : ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |